Therefore even if the switchboard is constructed using lift off type doors the switch room walls must be as a minimum 1 metre from all faces of the switchboard to comply with this requirement.
Main switchboard room requirements.
Limit values for humidity and air quality e g.
Stand alone packages.
This ifs assembly can incorporate normal main switchboard structures along with structures that incorporate multiple panel boards per structure usually two as well as dry type transform ers.
Together with the actual equipment sizes this defines the overall minimum dimensional requirements of the room.
An electrical room is a room or space in a building dedicated to electrical equipment.
Large buildings may have a main electrical room and subsidiary electrical rooms.
In order to design a good ventilation of switchgear and transformer rooms the air in the room must meet various requirements.
Article 408 contains the requirements for switchboards panelboards and distribution boards for light and power.
Main lv switchrooms will typically contain free standing switchboards and motor control centres mcc along with auxiliary equipment required for the room to function bus ducts cable containment distribution boards lighting small power air conditioning equipment fire fighting etc.
Openings or doorways should be at least 0 9 m wide by 2 2 m high to allow access to the switchboard room or enclosure where necessary.
Where a clear space of at least 3 m is provided in front of the switchboard and its equipment including its doors only one emergency exit path needs to be provided.
Space requirements for electrical rooms remote switchgear.
Integrated facilities switchboard ifs.
Unimpeded space of at least 0 6 metres around the switchboards with switchboard doors in any position and switchgear fully racked out position.
Electrical equipment may be for power distribution equipment or for communications equipment.
Each switchroom is unique and needs to be considered in relation to the specific equipment which will be installed.
Main equipment rooms distribution pathways and local branch equipment rooms.
Switchboard ifs that requires access from the front only.
There are three types of general interior electrical spaces that factor into new building design.
Dust content may also be set.
Switchgear placed in another service area near the genset room opens floor space and helps keep operators out of high decibel areas when gensets are in operation and protects delicate electronics from the heat and vibration associated with these machines.
Its size is usually proportional to the size of the building.
In some projects switchboard and panelboard installation may be taking on a new twist with distributed generation applications such as small wind and solar installations.